Sampling System for liquids or solids

DIN-EN: DN 15 – 100 / PN 10 – 40
ASME: NPS ½“ – 4“ / class 150 – 300
PT range: -40 < T < 230°C, vacuum 10-8 mbar

Spec Sheet
Certificate
Submit Enquiry

Design Features

Design Characteristics

  • free of cavity
  • closed system
  • maintenance free – self lubricating
  • pressureless sampling
  • defined representative sample quantity (25ml)
  • piggable
  • no flow interruption
  • simple and foolsafe handling
  • sampling in vacuum possible
  • fugitive emmission resp. clean air act certified (TA – Luft 2002 approval)
  • DGRL 97/23/EG

Functional Principle

Funktionsprinzip-Contiflow-GB

Design variations
• CONTIFLOW = Sampling plug valve with PTFE sleeve
• CONTIFLOW TRF = Sampling plug valve with PTFE sleeve and lined plug (pharmaceutic cip competent)
• CONTIFLOW TRF-A = Sampling plug valve with PTFE sleeve and lined body and plug (pharmaceutic cip competent)

Bottle connection
• PTFE-Adapter: for laboratory bottle with ISO-thread GL 32/45. Application: For less toxic resp. polluted media.
• Clamping Retainer: For fast and easy exchange of laboratory bottle, even for heated version.
• Needle system: closed needle system for laboratory bottle with septum (Butyl and PTFE). Needle System NH and NH-S with diverse internal diameter(2-6 mm). Application for high toxic resp. polluted media for spillnig eliminated an contamination free sampling.

Sampling-Flaschen-GB

PT-Diagram

PT-Diagramm-2015-GB

Operating temperatures < -30°C and > 220 °C have to be checked and approved by AZ according to the operating conditions.

Besides the P/T value of the sleeve the limitations of the valve bodies also have to be considered. Please refer to the EN 12516-1 resp. ASME B16.34 in order to choose a proper pressure rating (PN/class). The shown values refer to austenitic stainless steel 1.4408 (A351 Gr. CF8M).

1) For operating temperatures below -10°C low temperature / austenitic steels are required.
2) Sleeve: There are different sleeve materials / compounds available.

Materials

Standard body materials
• Carbon Steel 1.0619, ASTM A216 WCB
• Stainless Steel 1.4408, ASTM A351 CF8M
• Stainless Steel 1.4308, ASTM A351 CF8
• Unalloyed stainless steel casting (low Temp.) 1.1138, LCC/LCB/A352

Standard plug materials
• Stainless Steel 1.4408, ASTM A351 CF8M
• Stainless Steel 1.4308, ASTM A351 CF8

Special materials
• Alloy
• Monel
• Nickel
• Zirconium
• Titan
• Tantal
• other materials on request

Lining materials (Type TRF / TRF-A)
• PFA, PFA-conductive, FEP, PVDF

Sealing Systems

[table id=20 /]

Port Forms

Kuekenform-Contiflow

Dimensions

Techn-Daten_GB_Contiflow

Actuation

Hand-Auto-GB-Contiflow

1 Locking Devices
Pilot valve combinations, pad lock eyelets, linear key conception, indexing plunger arrestor.
read more […]

2 Plug stem extension
Solid construction in stainless steel with T-wrench, Standard extension 100 mm or 150 mm, non standard lengths are available on request
read more […]

3 Actuators
Actuators for mounting-flange acc. to DIN ISO 5211
read more […]

4 Ratched coupling
To usw on multiport valves with standard 90° actuator for bigger switchpositions than 90°
read more […]

5 Cover extension
Solid construction in stainless steel, Standard extension 100 mm or 150 mm high,  non standard lengths are available on request . Hexagonal bolts on adjustment ring freely accessible. Note: Don’t use with sealing FSN/FSN-SL and CASN/CASN-SL
read more […]